GC Capillary Columns

SGE's GC columns are manufactured end to end by SGE drawing on our five decades of capillary column innovation to provide you with separation solutions.

The column is the heart of a gas chromatograph , wherein the fundamental process of separation Takes place .its action is based on the fact that when a sample of gas or vapour is introduced into a column ,it spread by molecular diffusion to yield a concentration profile .As the sample moves through the column ,additional spread takes place but the band maintains its general shape, which is detected and recorded as the familiar chromatographic peak.

1) BP 624

  • US EPA 624 optimized column
  • Designed for volatiles analysis
  • Ideal for EPA624, SW-846 and 8240/8260 methods
  • Ideal for USP G43 method

Application Areas: EPA method 624, drinking water volatiles, chlorinated hydrocarbons, solvents

Operating Temperature: 1.0-3.0঩lm thickness 0യ 230/240쯰>

2) BP 20 (WAX)

  • Industry standard wax column.
  • Polar phase.
  • 240 - 280 ൰per temperature limit-dependent on film thickness.
  • Bonded and cross-linked.
  • Able to be solvent rinsed.

Application Areas: Alcohol, free acids, fatty acid methyl esters (FAMEs), aromatics, solvents, essential oils.
Applications FOO03, FOO24 FLA03, ALC03, ACI03, POL01, PHA13

3) BP 21 (FFAP)

  • Nitroterephthalic acid modified PEG.
  • Polar phase.
  • Ideal for low molecular weight acids.
  • 240/250 ൰per temperature limit.
  • Able to be solvent rinsed (water or methanol is NOT recommended for rinsing).
  • Bonded and cross-linked.

Application Areas: Volatile free acids, fatty acid methyl esters, alcohols, aldehydes, acrylates, ketones. Applications ACI02, SOL04.

4) PAH Column

Phase: BPX50, 0.25 μm
Column: 30 m x 0.25 mm
Average Linear Velocity: 39 cm/sec at 65 좲 /> (PAH) standard: 10 ng/ μL in dichloromethane
Final Temp.: 325 젼br /> 15 min Injection Temp.: 250 좲 /> Detector Type: MSD Autosampler: No
Carrier Gas: Helium, 9.7 psi
Liner Type: 4 mm ID Double Taper

GC Capillary Column Ferrules

picture

Signals that a ferrule is damaged include:


  • background noise from oxygen diffusinginto the system
  • column bleed catalyzed by oxidation
  • sample degradation
  • loss of sample
  • increase in detector signal noise
  • poor retention time reproducibility

General techniques for installing ferrules

  • Don't over tighten finger tighten column nut, then use wrench to tighten 1/4 turn
  • maintain cleanliness
  • bake out ferrules prior to use avoid contamination-fingerprints, oils
  • change ferrules when new columns or injector/detector parts are installed.

SEPTA

picture

The role of septa for GC analysis is key with many chromatographic problems caused as a resultof inappropriate septa material or rolex replica uk inappropriate handling of the septa.

Desired septa attributes:

  • Must reliably seal against the carrier gas pressure in the inlet.
  • Must be capable of being pierced by the syringe needle without pieces of the septa being deposited in the GC inlet system, which would be catastrophic to the chromatography.
  • Must be capable of being pierced and resealed time after time.
  • Must not be allowed to be contaminated or bleed material into the chromatographic system

Long Life Septa

Long life septa are designed for use with autosamplers and provide outstanding longevity (400+ injections) at inlet temperatures up to 400쯰>

Low Bleed High Temperature Septa

Low bleed high Temperature septa are designed for for manual injection at temperatures up to 400ecause of the low bleed they are ideal for use with Mass Spectrometers.

SYRING

picture

SGE syringes are available for GC and LC manual injection, and for the major brands of GC and HPLC autosamplers.
Use of microliter volume syringes often presents two concerns - delicate plungers, and proportionally large sample hold-up in the needle. SGE syringe options featuring Plunger Protection, Guided Plunger and SuperfleXଵngers help prevent bending or kinking of the plunger. Syringes with the Plunger-in-Needle feature permit the injection of very small sample volume.

Syringes and Accessories

picture

Syringe Selection and Technical Information

General Purpose Manual Syringes

0.5 - 5 μL NanoVolume
5 μL and 10 μL Metal Plunger
25 - 500 μL Metal Plunger
10 - 500 μL PTFE Tipped Plunger
1 - 100 μL PTFE Tipped Plunger

Syringe Valves

Syringes Pre-fitted with Syringe Valves
Valve Needles
SealTight™ Valves

GC Autosampler Syringes

Agilent Instruments
CTC Analytics
CTC PAL-XT and XCHANGE좲 /> Shimadzu Instruments
PerkinElmer Instruments
Thermo Scientifi c Instruments
Bruker/Varian Instruments

LC Manual Syringes

Beckman/Altex, Rheodyne, SSI
Instruments and Valco Valves
LC Autosampler Syringes
Hitachi Instruments
PerkinElmer Instruments
CTC PAL-XT and XCHANGE좲 /> Spark Holland Instruments
Thermo Scientifi c Instruments
Waters Instruments

LC Pump High Capacity Syringes

Instrument Syringes
1 - 100 mL PTFE Tipped Plunger
General - Replacement for Hamilton
Pump Syringes
Shimadzu Total Organic Carbon
Analyzer - TOC5000
Zymark

Special Purpose Syringes

MEPS™ - Micro Extraction by Packed
Sorbent
eVol텐S™
GC On-Column
0.5 L to 2 L Jumbo
Gas Sealing Gland
Headspace/Soil Gas
High Pressure
Syringe Accessories
Repeating Adaptor (RAX)
Syringe Racks
Heated Syringe Cleaner
Needle Cleaning Kit
Stylet Wires

GC Inlet Liners

picture

The GC Inlet liner is where the sample is introduced and vaporized into the gaseous phase. The Design of the liner is crucial, as is liner deactivation, to ensure reproducible and accurate chromatography. click for more info

UNIONS

picture

SGE Unions are available in two material types: stainless steel and glass-lined stainless steel (GLT™ lined unions).

Stainless steel example: straight through, reducing,tees, crosses and bulkheads

GLT™ lined unions are inert and mainly used for connecting fused silica tubing of various internal diameters.